Categories

1 C/O Relay Modules


Our Stores : 

 

Relay Modules
Description Relay Socket No. of channels Order Code Buy Now or
Enquire Now
1 C/O Standard

Download Datasheet

 


Knowledge Base
  • 1 C/O
    Contacts
  • Reverse blocking diode
  • 24VDC Coil
  • -ve / +ve or isolated looping by jumpers(site selectable)
  • OEN Relays
Directly Soldered 1 AS361-24V-OE  
2 AS362-24V-OE  
4 AS363-24V-OE  
8 AS365-24V-OE  
12 AS366-24V-OE  
16 AS367-24V-OE  
Socket Mounted 1 AS361-24V-S-OE  
2 AS362-24V-S-OE  
4 AS363-24V-S-OE
8 AS365-24V-S-OE
12 AS366-24V-S-OE
16 AS367-24V-S-OE
  • -Ve, +Ve or Isolated Coil looping can be done with the jumpers supplied with.
  • Availability & Prices for other relays (such as Omron G2RL) & coil voltages shall be quoted against specific request.
1 C/O Looped Coils

Download Datasheet
  • 1 C/O
    Contacts
  • Reverse blocking diode
  • 24VDC Coil
  • -Ve looped
    ( Factory set )
    OR
    +Ve looped
  • OEN Relays
Directly Soldered 1 AS351-24V-N-OE
2 AS352-24V-N-OE
4 AS353-24V-N-OE
8 AS355-24V-N-OE  
12 AS356-24V-N-OE
16 AS357-24V-N-OE
Socket Mounted 1 AS351-24V-N-S-OE
2 AS352-24V-N-S-OE
4 AS353-24V-N-S-OE
8 AS355-24V-N-S-OE
12 AS356-24V-N-S-OE
16 AS357-24V-N-S-OE
  • Availability & Prices for other relays (such as Omron G2RL) & coil voltages shall be quoted against specific request.
  • Order code shown above is for –Ve looped coils. Replace N with P for +Ve looping. Price remains same.
1 C/O Sugar cube Looped Coils

Download Datasheet
  • 1 C/O Contacts
  • Reverse blocking diode
  • 24VDC Coil
  • -Ve looped
    ( Factory set )
    OR
    +Ve looped
  • Sun hold Relays
Directly Soldered 1 AS401-24V-N-SH
2 AS402-24V-N-SH
4 AS403-24V-N-SH
8 AS405-24V-N-SH
12 AS406-24V-N-SH
16 AS407-24V-N-SH
  • Availability & Prices for other relays & coil voltages shall be quoted against specific request.
  • Order code shown above is for –Ve looped coils. Replace N with P  for +Ve looping.
    Price remains same. Availability for +Ve looped coils is 3 weeks
1 C/O Sugar Cube Isolated Coils

Download Datasheet
  • 1 C/O
  • Reverse blocking diode
  • 24VDC Coil
  • Isolated Coils
  • Sun hold Relays
Directly Soldered 1 AS411-24V-SH
2 AS412-24V-SH
4 AS413-24V-SH
8 AS415-24V-SH
12 AS416-24V-SH
16 AS417-24V-SH
  • Availability & Prices for other relays & coil voltages shall be quoted against specific request.
1 C/O High Volt. Coils

Download Datasheet
  • 1 C/O Contacts
  • 230VAC Coil*
  • Isolated Coils
  • OEN Relays
Directly Soldered 1 AS421-230VAC-OE
2 AS422-230VAC-OE  
4 AS423-230VAC-OE
6 AS424-230VAC-OE
8 AS425-230VAC-OE
16 AS427-230VAC-OE
Socket Mounted 1 AS421-230VAC-S-OE
2 AS422-230VAC-S-OE
4 AS423-230VAC-S-OE
6 AS424-230VAC-S-OE
8 AS425-230VAC-S-OE
16 AS427-230VAC-S-OE
  • * These modules are with basic relay of 24VDC coil along with suitable voltage converter.
  • Order Code shown above is for 230VAC coils. Replace 230VAC with other voltages 48VDC, 110VDC, 110VAC as required. Price remains same.
  • Availability & Prices for other relays (such as Omron G2RL) & coil voltages shall be quoted against specific request.
1 C/O 24VAC Coils

Download Datasheet
  • 1 C/O Contacts
  • 24VAC Coil*
  • Isolated Coils
  • OEN Relays
Directly Soldered 1 AS621-24VAC-OE
2 AS622-24VAC-OE
4 AS623-24VAC-OE
6 AS624-24VAC-OE
8 AS625-24VAC-OE
Socket Mounted 1 AS621-24VAC-S-OE
2 AS622-24VAC-S-OE
4 AS622-24VAC-S-OE
6 AS624-24VAC-S-OE
8 AS625-24VAC-S-OE
  • * These modules are with basic relay of 24VDC coil along with suitable voltage converter.
  • Availability & Prices for other relays (such as Omron G2RL) & coil voltages shall be quoted against specific request.
1 C/O Fuse at Pole with Fuse Fail Indication

Download Datasheet
  • 1 C/O
    Contacts
  • Reverse blocking diode
  • 24VDC Coil
  • -Ve looped
    ( Factory set )
    OR
    +Ve looped
  • OEN Relays
Directly Soldered 1 AS501-24V-N-OE-24VDC-2A
2 AS502-24V-N-OE-24VDC-2A
4 AS503-24V-N-OE-24VDC-2A
6 AS504-24V-N-OE-24VDC-2A
8 AS505-24V-N-OE-24VDC-2A
12 AS506-24V-N-OE-24VDC-2A
16 AS507-24V-N-OE-24VDC-2A
Socket Mounted 1 AS501-24V-N-S-OE-24VDC-2A
2 AS502-24V-N-S-OE-24VDC-2A
4 AS503-24V-N-S-OE-24VDC-2A
6 AS504-24V-N-S-OE-24VDC-2A
8 AS505-24V-N-S-OE-24VDC-2A
12 AS506-24V-N-S-OE-24VDC-2A
16 AS507-24V-N-S-OE-24VDC-2A
  • Order Code shown above is for –Ve looped coils, 24VDC Contact rating & 2A Fuse rating. Replace N with P for +Ve looping, 24VDC with 230V for 230VAC or 110VAC & 2A with 5A for 5 Amp fuse. Price remains same.
  • Availability & Prices for other relays (such as Omron G2RL) & coil voltages shall be quoted against specific request.
1 C/O with High volatge Coil & Fuse at poles with Fuse Fail Indication

Download Datasheet
  • 1 C/O Contacts
  • 230VAC Coil*
  • Isolated Coils
  • OEN Relays
Directly Soldered 1 AS801-230VAC-OE-24VDC-5A
2 AS802-230VAC-OE-24VDC-5A
4 AS803-230VAC-OE-24VDC-5A
8 AS805-230VAC-OE-24VDC-5A
Socket Mounted 1 AS801-230VAC-S-OE-24VDC-5A
2 AS802-230VAC-S-OE-24VDC-5A
4 AS803-230VAC-S-OE-24VDC-5A
8 AS805-230VAC-S-OE-24VDC-5A
  • *These modules are with basic relay of 24VDC coil along with suitable voltage converter.
  • Order Code shown above is for 230VAC Coil and 24VDC, 2A Contact Rating. Replace 230VAC with other voltages 48VDC, 110VDC, 110VAC as required & 24VDC with 230V for 230VAC or 110VAC contact rating & Fuse rating as required. Price remains same.
  • Availability & Prices for other relays (such as Omron G2RL) & coil voltages shall be quoted against specific request.
1 C/O Space Saver

Download Datasheet
  • 1 C/O Contacts
  • Reverse blocking diode
  • OEN Relays
Directly Soldered 8 AS789-24V-N-OE
(For -Ve looped coils)
AS789-24V-P-OE
(For +Ve looped coils)
  • Availability & Prices for other relays (such as Omron G2RL) & coil voltages shall be quoted against specific request.
  • Order code shown above is for –Ve looped coils. Replace N with P for +Ve looping.

Related Products